13X Molecular Sieve

Introduction

Molecular Sieve 13X is the sodium form of the type X crystal and has a much larger pore opening than the type A crystals. It will adsorb molecules with a kinetic diameter of less than 9 Angstrom (0.9 nm) and exclude those larger.
It also has the highest theoretical capacity of the common adsorbents and very good mass transfer rates. It can remove impurities too large to fit into a type A crystal and is commonly used to separate nitrogen from oxygen.

Technical specification

Model 13X
Color Light gray
Nominal pore diameter 10 angstroms
Shape Sphere Pellet
Diameter (mm) 1.7-2.5 3.0-5.0 1.6 3.2
Size ratio up to grade (%) ≥98 ≥98 ≥96 ≥96
Bulk density (g/ml) ≥0.7 ≥0.68 ≥0.65 ≥0.65
Wear ratio (%) ≤0.20 ≤0.20 ≤0.20 ≤0.20
Crushing strength (N) ≥35/piece ≥85/piece ≥30/piece ≥45/piece
Static H2O adsorption (%) ≥25 ≥25 ≥25 ≥25
Static CO2 adsorption (%) ≥17 ≥17 ≥17 ≥17
Water content (%) ≤1.0 ≤1.0 ≤1.0 ≤1.0
Typical Chemical Formula Na2O. Al2O3. (2.8±0.2) SiO2. (6~7)H2O
SiO2 : Al2O3≈2.6-3.0
Typical Application a) Removal of CO2 and moisture from air (air pre-purification) and other gases.
b) Separation of enriched oxygen from air. 
c) Removal of n-chained compositions from aromatics.
d) Removal of R-SH and H2S from hydrocarbon liquid streams (LPG, butane etc.)
e) Catalyst protection, removal of oxygenates from hydrocarbons (olefin streams).
f) Production of bulk oxygen in PSA units.

Application

– Removal of CO2 and moisture from air (air pre-purification) and other gases.
– Separation of enriched oxygen from air.
– Removal of mercaptans and hydrogen sulphide from natural gas.
– Removal of mercaptans and hydrpogen sulphide from hydrocarbon liquid streams (LPG, butane, propane etc.)
– Catalyst protection, removal of oxygenates from hydrocarbons (olefin streams).
– Removal of n-chained compositions from aromatics.
– Production of bulk oxygen in PSA units .
– Production of medical oxygen in small scale oxygen concentrators

Regeneration

Molecular sieve Type 13X can be regenerated by either heating in the case of thermal swing processes; or by lowering the pressure in the case of pressure swing processes.
To remove moisture from a 13X molecular sieve, a temperature of 250-300°C is required. A properly regenerated molecular sieve can give moisture dew points below -100°C, or mercaptan or CO2 levels below 2 ppm.
The outlet concentrations on a pressure swing process will depend on the gas present, and on the conditions of the process

Size

13X – Zeolites are available in beads of 1-2 mm(10×18 mesh), 2-3 mm(8×12 mesh), 2.5-5 mm(4×8 mesh) and as powder, and in pellet 1.6mm, 3.2mm.

Comments

To avoid damp and pre-adsorption of organic before running, or must to be reactivated.

Products

Activated Carbon

Molecular sieves for medical oxygenators

A measure to prevent infection

Ceramic grate sulfur noodles

Rashig's crimped rings

Prismatic springs

Products

We are up to date with technical innovations and implement them as part of our offer.

%

Satisfaction

Our products are of the highest possible quality. When you buy from us, you buy safely.

Years of experience

We know everything about our products. Practical knowledge acquired through years of presence in the industry.

Countries

Our brand has visited countries all over the world. We deliver products, among others to Germany, Sweden and the United States.

HurtGral - Your supplier of molecular sieves.

Contact

If you want to discuss your order, ask about products or discuss product specifications, please contact us.
Call +48 792 020 580 or use the contact form.

10 + 13 =

HurtGral - Your supplier of molecular sieves.

Ceramic packing, yeast, enzymes, additives for the food industry.